En  |  Ru

contrAA 800 D atomic absorption spectrometer

contrAA series atomic absorption spectrometers with linear continuum source

contrAA® 800 D are atomic absorption spectrometers with a linear continuum source, flame and electrothermal atomization in graphite furnace. contrAA® atomic absorption spectrometers mark a link between conventional AAS and ICP-OES, combine the best qualities of both methods: AAS simplicity and affordability with ICP-OES speed. Just one lamp allows identifying all the elements, metals and non-metals, at any wavelength. The optical system and the CCD detector create a high-resolution absorption spectrum for each sample, which provides exhaustive information about the latter. Spectrum display in 3D format drastically facilitates development of the method.

Main advantages:

  • one light source for fast sequential multi-element analysis w/o lamp change, heating, and adjustment;
  • a pyrometer for non-contact accurate online measurement of temperature;
  • expanded measurement range up to the fifth order;
  • semiquantitative analysis of unknown samples of metals and non-metals;
  • 3D visualization of spectra to identify complex analytical lines in high resolution;
  • high resolution optics for low noise level, precision and low detection limits;
  • analysis of hard-melting elements already at atomization temperature of 2600°C;
  • transverse heated graphite furnaces and current supply via integral contacts;
  • monitoring of dosing and atomization processes in the furnace with the aid of a video camera;
  • state-of-the-art background correction and spectral overlap algorithms;
  • automatic dosed introduction of samples into the flame with the smart dilution feature;
  • continuous batch-wise injection of microsamples into the flame using a segmented flow star (SFS).

Performance parameters

Material of samples / application: Polymers and plastics : Foods, feeds : Geological rocks : Environmental facilities : Metallurgical materials : Semiconductor manufacturing materials : Biological materials : Pharmaceutical manufacturing materials : Precious metals Analysis type: Multi-element Detection limit range: Ppb shares – % Wavelength range, nm: 185–900 Number of elements in a sample: 10-50 Number of samples per day: 1-100 Sample atomization type: Flame (acetylene/air, acetylene/nitrous oxide) and electrothermal atomization in graphite furnace Analysis of As, Se, Sb, Hg, Bi, Te, and other hydride-forming elements: Option TDS level, g/l: 100 Refitting with an automatic sample changer: Option Detector type: CCD array Background correction: Digital Monochromator type: Echelle Analysis type: Fast sequential Radiation source: Xenon lamp Dimensions (L × W × H), mm: 780 × 775 × 625 Weight, kg: 180